.\" $XdotOrg: $
.\"
.\" Copyright \(co Digital Equipment Corporation, 1996
.\"
.\" Permission to use, copy, modify, distribute, and sell this
.\" documentation for any purpose is hereby granted without fee,
.\" provided that the above copyright notice and this permission
.\" notice appear in all copies. Digital Equipment Corporation
.\" makes no representations about the suitability for any purpose
.\" of the information in this document. This documentation is
.\" provided ``as is'' without express or implied warranty.
.\"
.\" Copyright 1999, 2005 Sun Microsystems, Inc. All Rights Reserved
.\"
.\" Permission is hereby granted, free of charge, to any person obtaining a
.\" copy of this software and associated documentation files (the "Software"),
.\" to deal in the Software without restriction, including without limitation
.\" the rights to use, copy, modify, merge, publish, distribute,
.\" sublicense, and/or sell copies of the Software, and to permit persons
.\" to whom the Software is furnished to do so, subject to the following
.\" conditions:
.\"
.\" The above copyright notice and this permission notice shall be
.\" included in all copies or substantial portions of the Software.
.\"
.\" THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
.\" EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF
.\" MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT.
.\" IN NO EVENT SHALL THE COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM,
.\" DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR
.\" OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR
.\" THE USE OR OTHER DEALINGS IN THE SOFTWARE.
.\"
.\" Except as contained in this notice, the names of the copyright holders
.\" shall not be used in advertising or otherwise to promote the sale, use
.\" or other dealings in this Software without prior written authorization
.\" from said copyright holders.
.\"
.\" X Window System is a trademark of The Open Group.
.\"
.TH DPMSSetTimeouts __libmansuffix__ __xorgversion__ "X FUNCTIONS"
.SH NAME
DPMSSetTimeouts \- permits applications to set the timeout values
used by the X server for DPMS timings
.SH SYNOPSIS
.PP
.nf
\fBcc\fR [ \fIflag\fR \&.\&.\&. ] \fIfile\fR \&.\&.\&. -\fBlXext\fR [ \fIlibrary\fR \&.\&.\&. ]
\&#include <X11/extensions/dpms.h>
.HP
.B Status DPMSSetTimeouts
(
.br
Display *\fIdisplay\fP\^,
.br
CARD16 \fIstandby\fP\^,
.br
CARD16 \fIsuspend\fP\^,
.br
CARD16 \fIoff\fP\^
);
.if n .ti +5n
.if t .ti +.5i
.SH ARGUMENTS
.TP
.I display
Specifies the connection to the X server
.TP
.I standby
Specifies the new standby timeout in seconds
.TP
.I suspend
Specifies the new suspend timeout in seconds
.TP
.I off
Specifies the new off timeout in seconds
.SH DESCRIPTION
.LP
The DPMSSetTimeouts function permits applications to set the timeout values
used by the X server for Display Power Management Signaling (DPMS) timings.
.LP
The value \fIstandby\fP is the amount of inactivity time, in seconds, before
standby mode is invoked. The actual
effects of this mode are dependent on the characteristics of the monitor and
frame buffer card. Standby mode is
implemented by shutting off the horizontal sync signal, and pulsing the vertical
sync signal. Standby mode
provides the quickest monitor recovery time. Note also that many monitors
implement this mode identical to
suspend mode. A value of zero disables the standby mode.
.LP
The value \fIsuspend\fP is the amount of time of inactivity, in seconds, before
the second level of power
savings is invoked. Suspend mode's physical and electrical characteristics are
implementation defined. For DPMS
compliant hardware, setting the suspend mode is implemented by pulsing the
horizontal sync signal and
shutting off the vertical sync signal. In general, suspend mode recovery is
considered to be slower than
standby mode, but faster than off mode. However it may vary from monitor to
monitor. As noted above, many
monitors implement this mode identical to the standby mode. A value of zero
disables this mode.
.LP
The value \fIoff\fP is the amount of time of inactivity,in seconds, before the
third and final level of power
savings is invoked. Off mode's physical and electrical characteristics are
implementation defined. In DPMS
compliant hardware, it is implemented by shutting off both horizontal and
vertical sync signals, resulting in
powering down of the monitor. Recovery time is implementation dependent.
Usually the recovery time is very
close to the power-up time of the monitor. A value of zero disables this mode.
.LP
Chronologically, \fIstandby\fP mode occurs before or simultaneously with
\fIsuspend\fP mode, and
\fIsuspend\fP mode must occur before or simultaneously with \fIoff\fP mode.
Therefore, non-zero mode timeout
values must be greater than or equal to the timeout values of earlier modes. If
inconsistent values are
supplied, a BadValue error will result.
.SH "RETURN VALUES"
.TP 15
TRUE
The
.I DPMSSetTimeouts
function returns TRUE when the function has succeeded.
.SH ERRORS
.TP 15
.SM BadValue
An argument is out of range.
.SH "SEE ALSO"
.BR DPMSCapable (__libmansuffix__),
.BR DPMSInfo (__libmansuffix__),
.BR DPMSGetTimeouts (__libmansuffix__)
|